Patient range Adult, pediatric, neonate
NIBP Measurement method Oscillometric
NIBP Measurement range 0 kPa – 38.67 kPa (0 mmHg – 290 mmHg)
NIBP Measurement mode Arm Measurement
Waveform Biphasic
Energy Sequence 150 J, 200 J
Analysis Time 9 seconds
Audio Indications 20 distinct voice instructions
Temperature Range 37°C to 42°C
Temperature Accuracy ± 0.5°C
Warm-up Time < 45 s (20°C to 36°C)
Power Consumption 250 VA
Temperature Range 37°C to 42°C
Temperature Accuracy ± 1.0°C
Warm-up Time < 45 s (20°C to 36°C)
Power Consumption 80 VA
Display 7-inch screen
Waveform Biphasic
Manual with Sync mode 2, 5, 7, 10, 20, 30, 50, 70, 100, 150, 200, 300, 360 joules
AED mode Auto analyze and charge x 3 with programmable auto energy level selection.
Display 12.1” LCD display
Ultrasound frequency 1024 (1 ± 10%) kHz
Max output intensity < 10 MW/cm2
FHR measurement range 30 bpm ~ 240 bpm
Display OLED 160 x 128 dot matrix display
Storage Built-in TF card storage for up to 2 GB
Standard Sensitivity 10 mm/mV ± 5%
Sensitivity Shift ≤ ± 10%
Control System Air-temp control, Skin-temp control & Humidity control
Display LED display
Air Temperature Control range 25°C ~ 37°C (Override : 37°C ~ 39°C)
Baby Temperature Control range 25°C ~ 37°C (Override : 37°C ~ 39°C)
Control System Air-temp control & Skin-temp control
Display LED display
Air Temperature Control range 25°C ~ 37°C (Override : 37°C ~ 39°C)
Baby Temperature Control range 25°C ~ 37°C (Override : 37°C ~ 39°C)
Control System Air-temp control
Display LED display
Air Temperature Control range 25°C ~ 37°C
Baby Temperature Control range
Control System Microprocessor based temperature control system
Control Modes Preheat, Manual and Skin-temp mode
Manual : Heater output 0-100%, 10% increments
Skin-temp : Control range 25 °C ~ 37 °C
Channel Single channel infusion
Volume (VTBI) 1 ml ~ 9999.9 ml ( 0.1 ml increment)
Accuracy Flow rate: ≤ ± 3 %
Mechanical: ≤ ± 2 %
KVO Rate 1 ml/h (1 ml/h ~ 300 ml/h)
3 ml/h (greater than 300 ml/h)
Channel Single channel infusion
Infusion Volume 0 ml ~ 9999 ml ( 0.1ml increment)
Infusion Rate 0.01 ml/h ~ 1200 ml/h (0.01ml/h increment)
KVO Rate 0.01 ml/h – 5 ml/h
Tidal Volume 20 ml ~ 500 ml
Standard Ventilation Mode VCV, SIMV, PSV, PCV, CPAP, Manual, SIGH
Application Adult/ Pediatric Invasive
Pressure Range 5 mbar ~ 80 mbar
Tidal Volume 10 ml ~ 300 ml
Standard Ventilation Mode CMV, IMV, CPAP, Manual
Application Pediatric
Inspiratory Flow 3 L/min ~ 20 L/min
Tidal Volume 20 ml ─ 2500 ml
Configurations Trolley or Ceiling Pendant
Respiratory Rate 1 bpm ─ 40 bpm (V-SIMV/P-SIMV/PRVC-SIMV)
4 bpm ─ 100 bpm ( VCV/PCV/PRVC)
Psupport 0 kPa ─ 6 kPa
Light Source 8 Blue LED lights
Wavelength 450 to 475nm
LED Lamp-life 1,00,000 hours
Intensity Control Low : 25 ~ 35 μW /cm2/nm
High : 35 ~ 55 μW /cm2/nm
Standard Parameter 5‐lead ECG, RESP, HR, NIBP, SpO2(F‐5), 1‐TEMP, PR
Patient Groups Neonate, Pediatric, Adults
Trace 9 waveform (ECG,SpO2, RESP)
ECG Lead Mode 5–lead (R, L, F, N, C) for leads I, II, III, V, aVR, aVF, aVL
Type Adult
Stroke volume 800 ml
Resuscitator volume 1630 ml
Bag reservoir volume 2000 ml
Type Pediatric
Stroke volume 350 ml
Resuscitator volume 680 ml
Bag reservoir volume 1600 ml
Type Neonatal
Stroke volume 150 ml
Resuscitator volume 250 ml
Bag reservoir volume 600 ml
KVO Rate 0.1 – 5ml/h (steps : 0.1ml/h)
Injection Compliance Adaptable for 5 syringe sizes
Preset Volume Range 0.1 ml – 1999.9 ml
Occlusion System 3-level alarming system
Channel Single channel infusion
Volume (VTBI) 0 ml – 9999 ml
Injection Compliance Adaptable for 6 syringe sizes
Accuracy ≤ ±2 %
Channel Dual channel infusion
Volume (VTBI) 0.1 ml – 1999.9 ml
Injection Compliance Adaptable for 10 syringe sizes
Accuracy ≤ ± 3 %
Tidal Volume 0 ml – 1500 ml
Gas Supply O2, 0.28 to 0.6 MPa
Ventilation Modes A/C, SIMV, SPONT, Manual, VCV+SIGH
Respiratory Rate 4 bpm – 40 bpm (SIMV)
4 bpm – 99 bpm (A/C)
Vital Parameters
Type AType BType C
4 Parameters (NIBP,SpO2, PR, Temp)3 Parameters (SpO2, PR, Temp)3 Parameters (NIBP, SpO2, PR)
Display 240 x 320 dot matrix colour TFT
NIBP Measurement range Adult: 30-255 mmHg
Paediatric: 30-160 mmHg 
NIBP Mode Auto, Manual, STAT
Vital Parameters 3 Parameters (SpO2 (with PR), NIBP, & 1-channel TEMP)
NIBP Measurement range Systolic Adult 50 ~ 265 mmHg Child 25 ~ 135 mmHg Diastolic Adult 15 ~ 220 mmHg Child 12 ~ 110 mmHg MAP Adult 25 ~ 245 mmHg Child 18 ~ 120 mmHg
NIBP Mode Manual, Auto
NIBP Parameters Sys, Dia, MAP